Neonatal Resuscitation Supplies and Equipment List
Suction Equipment
Bulb Syringe
- Material Composition:
Typically made of medical-grade silicone or soft rubber with hypoallergenic properties
-
Technical Specifications:
- Volume Capacity: 20-30 mL
- Recommended Suction Pressure: 50-80 mmHg
- Recommended Insertion Depth: 3-4 cm maximum
-
Clinical Applications:
Primary use for immediate post-delivery airway clearance in spontaneously breathing newborns
-
Procedural Guidelines:
- Clear mouth before nasal passages
- Maintain infant in slight Trendelenburg position
- Limit suctioning to maximum 5-10 seconds per attempt
-
Potential Complications:
Risks include mucosal trauma, vagal stimulation, and potential bradycardia if excessive force applied
Mechanical Suction and Tubing
-
Device Specifications:
- Pressure Range: 80-120 mmHg (adjustable)
- Flow Rate: 20-30 L/minute
- Power Source: Electrical/Battery backup
-
Tubing Characteristics:
- Material: Medical-grade PVC or silicone
- Length: 1.5-2 meters
- Diameter: 4-6 mm internal diameter
- Sterility: Single-use, disposable configuration recommended
-
Infection Control:
Requires strict adherence to sterilization protocols between patient uses
-
Performance Indicators:
- Consistent, controlled negative pressure
- Quick response time
- Minimal noise generation
Suction Catheters
-
Size Specifications:
Size Recommended Use Typical Gestational Age SF (5-6F) Extremely Premature Infants < 28 weeks 10F Very Low Birth Weight 28-32 weeks 12-14F Full-Term Newborns ≥ 37 weeks -
Material Properties:
Soft, flexible polyvinyl chloride (PVC) with smooth, atraumatic tips
-
Technical Limitations:
- Maximum recommended insertion depth: 5-6 cm
- Maximum suction duration: 10 seconds
- Recommended suction pressure: 80-100 mmHg
8F Orogastric Tube
-
Physical Characteristics:
- Size: 8 French (2.67 mm external diameter)
- Length: Typically 40-45 cm
- Material: Medical-grade silicone or polyvinyl chloride (PVC)
-
Accompanying Equipment:
- 20-mL Syringe: Graduated, luer-lock compatible
- Lubricant: Water-soluble, sterile medical lubricant
-
Clinical Applications:
- Gastric decompression
- Meconium removal
- Air evacuation to prevent respiratory compromise
-
Insertion Guidelines:
- Verify correct placement via auscultation
- Limit insertion time to 10-15 seconds
- Measure insertion depth based on infant's size
-
Potential Complications:
- Esophageal perforation
- Gastric mucosal damage
- Inadvertent respiratory tract insertion
Tracheal Aspirator
-
Device Specifications:
- Specialized Suction Catheter Design
- Dedicated to Lower Respiratory Tract Clearance
- Sterilizable or Single-Use Configuration
-
Technical Parameters:
Parameter Recommended Range Suction Pressure 80-100 mmHg Insertion Depth 4-5 cm maximum Suction Duration 3-5 seconds maximum -
Specific Use Scenarios:
- Meconium-stained amniotic fluid management
- Thick secretion removal in lower airways
- Immediate post-delivery airway clearance
-
Clinical Considerations:
- Only used in specific high-risk scenarios
- Requires advanced training for proper use
- Potential for triggering laryngospasm or bradycardia
-
Recommended Protocols:
- Direct visualization of tracheal opening
- Gentle, controlled suction technique
- Immediate assessment of infant's response
Positive-Pressure Ventilation Equipment
Device for Delivering Positive-Pressure Ventilation
-
Device Types:
- T-piece Resuscitator
- Self-Inflating Bag (e.g., Ambu bag)
- Flow-Inflating Bag
-
Technical Specifications:
Parameter Recommended Range Pressure Range 20-30 cm H₂O initial inflation Sustained Pressure 15-25 cm H₂O Peak Inspiratory Time 2-3 seconds -
Performance Criteria:
- Ability to provide consistent, controlled ventilation
- Precise pressure regulation
- Minimal air leakage
-
Critical Considerations:
Must be calibrated and tested before each use to ensure accurate pressure delivery and prevent potential lung injury
Face Masks
-
Size Specifications:
Size Gestational Age Weight Range Preterm Mask < 32 weeks < 1500 g Term Mask ≥ 37 weeks ≥ 2500 g -
Material Characteristics:
- Soft, flexible medical-grade silicone
- Anatomically contoured design
- Cushioned edges to prevent skin trauma
-
Fitting Criteria:
Must create an effective seal from chin to bridge of nose with minimal air leakage
Oxygen Source
-
Source Types:
- Wall-mounted oxygen supply
- Portable oxygen cylinders
- Oxygen concentrators
-
Technical Requirements:
Parameter Specification Purity 99% minimum Pressure Range 50-55 PSI Flow Rate Capability 0-15 L/minute -
Safety Considerations:
- Regular pressure and flow rate calibration
- Backup oxygen source required
- Proper storage and handling protocols
Compressed Air Source
-
Source Types:
- Wall-mounted compressed air system
- Portable air compressors
- Medical-grade air cylinders
-
Technical Specifications:
Parameter Specification Purity 99.5% medical-grade Pressure Range 50-55 PSI Flow Rate 0-15 L/minute -
Critical Considerations:
- Must be compatible with oxygen blender
- Regular maintenance and filtration
- Backup air source recommended
Oxygen Blender
-
Device Specifications:
- Precision mixing of oxygen and compressed air
- Flow rate set to 10 L/min standard configuration
- Adjustable FiO2 (Fraction of Inspired Oxygen) range: 21-100%
-
Tubing Characteristics:
Parameter Specification Material Medical-grade, non-reactive plastic Length 1.5-2 meters Internal Diameter 4-6 mm -
Performance Requirements:
Must provide consistent, precise oxygen concentration with minimal variability
Pulse Oximeter
-
Technical Specifications:
Parameter Specification Measurement Range 70-100% Accuracy ± 2-3% at 70-100% Response Time < 3 seconds -
Sensor Characteristics:
- Neonatal-specific adhesive sensor
- Disposable, single-patient use cover
- Multiple size options for preterm to term infants
-
Placement Considerations:
Preferential placement on right hand or right wrist to most accurately reflect preductal oxygen saturation
Target Oxygen Saturation Table
-
Oxygen Saturation Guidelines:
Postnatal Age Target SpO₂ 1 minute 60-65% 3 minutes 70-75% 5 minutes 80-85% 10 minutes 85-95% -
Interpretation Guidelines:
- Dynamic, progressive oxygen saturation targets
- Individualized based on gestational age and clinical condition
- Continuous monitoring and adjustment required
Stethoscope
-
Specialized Neonatal Configuration:
- Smaller chest piece (15-19 mm diameter)
- Lightweight design (under 100 grams)
- Enhanced acoustic sensitivity
-
Acoustic Performance:
Parameter Specification Frequency Range 20-1000 Hz Sound Amplification 20-40 dB Noise Reduction < 10 dB background interference -
Clinical Applications:
- Heart rate assessment
- Breath sounds evaluation
- Chest compression effectiveness monitoring
Laryngeal Mask
-
Size Specifications:
Size Weight Range Typical Use Size 1 2-5 kg Premature and Term Newborns Size 1.5 5-10 kg Larger Newborns -
Technical Characteristics:
- Medical-grade silicone construction
- Anatomically designed supraglottic seal
- Integrated inflation line
- Comes with 5-mL syringe for precise cuff inflation
-
Performance Criteria:
- Seal Pressure: 20-25 cm H₂O
- Ventilation Efficiency: 85-90%
- Minimal risk of esophageal insufflation
Orogastric Tube
-
Tube Specifications:
Parameter Specification Size 5F or 6F Material Soft, medical-grade PVC Length 40-45 cm -
Specific Use Conditions:
- Designed for use with laryngeal mask insertion ports
- Used for stomach decompression
- Prevents potential respiratory compromise
-
Insertion Guidelines:
- Maximum insertion depth: 10-12 cm
- Verify placement through auscultation
- Use with caution to prevent mucosal damage
Cardiac Monitor
-
Monitoring Capabilities:
- Continuous ECG tracking
- Heart rate range: 60-240 beats per minute
- Real-time arrhythmia detection
-
Lead Specifications:
Parameter Specification Number of Leads 3-5 disposable adhesive electrodes Electrode Size 1-2 cm diameter, neonatal-specific Placement Right shoulder, left shoulder, lower left chest -
Performance Metrics:
- Accuracy: ± 2 beats per minute
- Response Time: < 3 seconds
- Ability to detect bradycardia (< 100 bpm)
Intubation Equipment
Laryngoscope
-
Blade Types and Specifications:
Blade Size Patient Type Blade Length Typical Use No. 0 (Straight) Preterm Infants 70-80 mm Extremely low birth weight (<1000g)< /td> No. 1 (Straight) Term Infants 90-100 mm Full-term newborns (2.5-4 kg) -
Material Composition:
- Handle: Stainless steel or fiber-optic materials
- Blade: Stainless steel with smooth, polished edges
- Finish: Autoclavable and corrosion-resistant
-
Technical Performance:
- Light Intensity: 2.5-3.6V halogen or LED
- Color Temperature: 3000-4000K for optimal visibility
- Ergonomic Design: Lightweight, balanced grip
Extra Bulbs and Batteries
-
Battery Specifications:
- Type: Lithium or Alkaline
- Voltage: 2.5-3.6V
- Recommended Backup: Minimum 2 complete sets
-
Bulb Characteristics:
- Type: Halogen or LED replacement
- Voltage Compatibility: Match laryngoscope specifications
- Expected Lifespan: 50-100 hours of continuous use
-
Emergency Preparedness:
Critical for maintaining continuous illumination during intubation procedures
Endotracheal Tubes
-
Size Specifications:
Internal Diameter Estimated Birth Weight Gestational Age 2.5 mm <1 kg 23-28 weeks 3.0 mm 1-1.5 kg 29-32 weeks 3.5 mm 1.5-2.5 kg 33-36 weeks -
Material Properties:
- Composition: Medical-grade PVC or silicone
- Surface: Smooth, lubricated exterior
- Design: Uncuffed tubes for neonatal use
-
Critical Considerations:
- Must be non-toxic and sterile
- Radiopaque marking for verification
- Single-use, individually packaged
Stylet
-
Functional Characteristics:
- Purpose: Provide temporary rigidity for tube insertion
- Material: Malleable metal core with protective coating
- Flexibility: Adjustable curvature
-
Usage Guidelines:
- Optional but recommended for difficult intubations
- Remove immediately after successful tube placement
- Prevent over-manipulation to avoid mucosal damage
-
Size Compatibility:
Must match endotracheal tube diameter precisely
Measuring Tape
-
Specifications:
- Length: 50-100 cm
- Material: Disposable, non-latex medical tape
- Markings: Precise centimeter and inch measurements
-
Primary Uses:
- Determine endotracheal tube insertion depth
- Calculate weight-based medication dosages
- Assess infant's anthropometric measurements
-
Clinical Importance:
Critical for preventing accidental deep or shallow intubation
Endotracheal Tube Insertion Depth Table
-
Depth Calculation Method:
Calculated using formula: (Weight in kg × 3) + 6 = Insertion depth in cm
-
Depth Reference Table:
Birth Weight Tube Size Calculated Depth 1 kg 2.5 mm 9 cm 1.5 kg 3.0 mm 10.5 cm 2 kg 3.5 mm 12 cm -
Clinical Guidance:
- Always confirm placement via auscultation
- Use capnography for definitive confirmation
- Recheck depth after any patient movement
Scissors
-
Specifications:
- Type: Medical-grade stainless steel
- Length: 11-14 cm
- Design: Blunt/sharp tips for safety
-
Primary Uses:
- Cut umbilical cord
- Trim endotracheal tube if necessary
- Cut tape or bandages
-
Sterilization Requirements:
Must be autoclavable or disposable
Tube Securing Device
-
Tape Characteristics:
- Type: Hypoallergenic, waterproof medical tape
- Adhesive: Gentle, skin-friendly
- Width: 1-2 cm
-
Specialized Securing Devices:
- Designed to minimize skin trauma
- Adjustable tension mechanism
- Compatible with various tube sizes
-
Application Guidelines:
- Secure without excessive tension
- Allow for minor tube movement
- Regularly reassess tube position
Alcohol Pads
-
Composition:
- Alcohol Content: 70% Isopropyl
- Size: 2x2 inches or 3x3 inches
- Packaging: Individual sterile packets
-
Primary Uses:
- Skin preparation before procedures
- Cleaning equipment surfaces
- Disinfection of small areas
-
Storage Considerations:
- Keep in sealed, cool environment
- Check expiration dates regularly
- Avoid direct sunlight
Carbon Dioxide Detector
-
Detection Types:
- Colorimetric CO2 Detector
- Electronic Capnograph
-
Colorimetric Detector Specifications:
- Color Change Mechanism: pH-sensitive paper
- Detection Range: 2-6% CO2
- Single-use, disposable design
-
Capnograph Features:
- Digital CO2 measurement
- Continuous real-time monitoring
- Alarm systems for abnormal readings
-
Clinical Importance:
Confirms endotracheal tube placement and ventilation effectiveness
Medications
Epinephrine
-
Concentration and Dilution:
Concentration Volume Total Medication 0.1 mg/mL 10 mL 1 mg -
Pharmacological Classification:
Sympathomimetic amine, alpha and beta-adrenergic receptor agonist
-
Clinical Indications:
- Cardiac arrest
- Severe bradycardia unresponsive to ventilation
- Profound hypoxia
-
Dosage Considerations:
- Initial dose: 0.01-0.03 mg/kg
- Administered via intravascular route
- Can be repeated every 3-5 minutes if needed
-
Potential Side Effects:
- Tachycardia
- Hypertension
- Arrhythmias
Normal Saline
-
Packaging Options:
Container Type Volume Primary Use Bag 100 mL Volume Expansion Bag 250 mL Volume Expansion Prefilled Syringes Various Quick Administration -
Composition:
0.9% Sodium Chloride in Water for Injection
-
Clinical Applications:
- Volume resuscitation
- Treating hypovolemic shock
- Vascular access maintenance
-
Administration Guidelines:
- Typical bolus: 10 mL/kg
- Can be repeated if inadequate response
- Administer slowly over 5-10 minutes
Dextrose 10%
-
Product Specification:
- Concentration: 10% Glucose Solution
- Volume: 250 mL (Optional)
- Sterile, Pyrogen-free Solution
-
Physiological Purpose:
Provides readily metabolizable glucose to prevent and treat neonatal hypoglycemia
-
Indications:
- Blood glucose < 40 mg/dL
- Symptomatic hypoglycemia
- Prolonged resuscitation
-
Administration Protocol:
- Bolus: 2-4 mL/kg
- Can be repeated if persistent hypoglycemia
- Monitor blood glucose levels
Normal Saline for Flushes
-
Composition:
0.9% Sodium Chloride, USP (United States Pharmacopeia) Standard
-
Primary Functions:
- Maintaining IV line patency
- Clearing medication lines
- Preventing medication incompatibility
-
Technical Specifications:
- Sterile, Single-use Prefilled Syringes
- Typical Volume: 3-10 mL
- pH: 4.5-7.0
-
Usage Guidelines:
- Flush before medication administration
- Flush after medication administration
- Use gentle, consistent pressure
- Avoid forceful injection
Syringes
-
Syringe Size Specifications:
Volume Typical Use Precision 1 mL Precise medication doses 0.01 mL increments 3 mL Small volume medications 0.1 mL increments 5 mL Medium volume medications 0.2 mL increments 20-60 mL Volume expansion, fluid administration 1 mL increments -
Material Composition:
Medical-grade polypropylene with low-binding, sterile construction
-
Compatibility:
- Luer-lock connections
- Clear calibration markings
- Latex-free options available
Fluid Connectors
-
Types of Connectors:
- Three-way Stopcocks
- Allows multiple fluid pathway control
- Rotating mechanism for fluid direction
- Fluid-Dispensing Connectors
- Quick-connect systems
- Minimize contamination risk
- Three-way Stopcocks
-
Technical Features:
- Made from medical-grade plastics
- Autoclavable or single-use options
- Luer-lock compatibility
-
Clinical Applications:
- Medication administration
- IV line management
- Fluid pathway redirection
Emergency Medication Dosage Table
-
Weight Range Coverage:
Designed for neonates weighing 0.5 to 4 kg
-
Purpose:
- Standardized medication dosing
- Rapid reference for emergency calculations
- Reduces medication dosing errors
-
Typical Included Medications:
- Epinephrine
- Normal Saline
- Dextrose
-
Calculation Basis:
- Weight-based dosing
- Standardized concentration references
- NRP protocol compliance
Umbilical Vessel Catheterization Supplies
Sterile Gloves
-
Material Composition:
- Latex or Nitrile
- Powder-free synthetic material
- Surgical grade quality
-
Technical Specifications:
Parameter Specification Size Range 6.0 - 8.5 Thickness 0.10-0.12 mm AQL (Acceptable Quality Limit) 1.5 -
Clinical Requirements:
- Sterility guaranteed by manufacturer
- Single-use only
- Individually packaged
-
Infection Control Considerations:
Essential for preventing contamination during invasive procedures, maintaining strict aseptic technique
Antiseptic Prep Solution
-
Recommended Formulations:
- Chlorhexidine-Alcohol (>0.5% chlorhexidine in 70% isopropyl alcohol)
- Povidone-Iodine (10%)
- 70% Isopropyl Alcohol
-
Application Characteristics:
Property Specification Contact Time 30-60 seconds Antimicrobial Spectrum Broad-spectrum (Gram+ and Gram- bacteria) Drying Time 15-30 seconds -
Precautions:
- Avoid contact with eyes
- Not recommended for patients with iodine allergies
- Do not use on premature infants with <1500g weight if using iodine-based solutions
Umbilical Tape
-
Material Characteristics:
- Non-absorbable, woven cotton or polyester
- Sterile, single-use
- Width: 1/4 inch (6mm)
-
Functional Properties:
- High tensile strength
- Minimal tissue reaction
- Easy to manipulate
-
Clinical Applications:
- Ligating umbilical stump
- Temporary vessel occlusion
- Securing catheter placement
-
Handling Precautions:
Must maintain sterility, handle with sterile technique
Small Clamp (Hemostat)
-
Technical Specifications:
Parameter Specification Material Stainless Steel (Surgical Grade) Length 4-5 inches (10-12.5 cm) Tip Design Curved, Serrated -
Clinical Functions:
- Vessel occlusion
- Tissue manipulation
- Maintaining sterile field
-
Types:
- Mosquito Hemostat (Fine, delicate)
- Kelly Clamp (Robust, stronger grip)
-
Sterilization Requirements:
Autoclavable, must be sterilized between uses
Forceps
-
Classification:
- Optional accessory in umbilical catheterization
- Used for precise tissue manipulation
-
Technical Specifications:
Type Characteristics Adson Forceps Fine tips, delicate tissue handling Tissue Forceps Serrated tips, stronger grip -
Material Composition:
Surgical stainless steel, autoclavable
-
Usage Precautions:
- Minimal pressure to prevent tissue damage
- Maintain strict sterility
- Use only when absolutely necessary
Scalpel
-
Technical Specifications:
Parameter Specification Blade Size #11 or #15 Material Surgical Stainless Steel Design Triangular, Sharp Point -
Specific Uses:
- Creating precise incision in umbilical stump
- Preparing site for catheter insertion
- Minimal invasive intervention
-
Safety Considerations:
- Single-use, disposable
- Sterile packaging
- Proper disposal in sharps container
-
Handling Precautions:
Extreme care to prevent accidental injury, use with utmost precision
Umbilical Catheters
-
Catheter Specifications:
Parameter Specification Lumen Type Single Lumen Sizes 3.5F or 5F Material Radiopaque Polyurethane -
Clinical Applications:
- Umbilical venous access
- Medication administration
- Emergency fluid resuscitation
-
Insertion Considerations:
- Verify correct placement via X-ray
- Limit insertion depth based on infant weight
- Monitor for potential complications
-
Safety Parameters:
- Sterile, single-use
- Marked with depth indicators
- Flexible tip to minimize vessel trauma
Three-Way Stopcock
-
Technical Specifications:
Parameter Specification Material Medical-grade Polycarbonate Connections 3 Port (Luer Lock) Rotation 360-degree Adjustable -
Functional Capabilities:
- Multiple fluid pathway control
- Allows simultaneous connection of multiple lines
- Enables precise fluid management
-
Clinical Applications:
- Medication administration
- Fluid infusion
- Pressure monitoring
-
Handling Precautions:
- Ensure tight connections
- Rotate carefully to prevent contamination
- Check for air locks before use
Syringes
-
Syringe Specifications:
Parameter Specification Volume 3-5 mL Type Luer Lock Graduation 0.1 mL increments -
Clinical Uses:
- Medication administration
- Catheter flushing
- Precise volume measurement
-
Material Characteristics:
- Latex-free
- Sterile, single-use
- Transparent for clear visibility
-
Accuracy Considerations:
Critically important for neonatal dosing precision
Needle or Puncture Device
-
Device Specifications:
Parameter Specification Type Needleless Access System Material Medical-grade Plastic Compatibility Universal Luer Lock Connections -
Safety Features:
- Eliminates needle stick injury risk
- Closed system design
- Prevents contamination
-
Clinical Application:
Provides secure, sterile access point for medication administration and fluid management
-
Infection Control:
- Single-use
- Sterile packaging
- Designed for minimal manipulation
Normal Saline for Flushes
-
Solution Characteristics:
Parameter Specification Concentration 0.9% Sodium Chloride pH 7.4 ± 0.5 Packaging Sterile, Single-use Vials -
Clinical Uses:
- Catheter flushing
- Maintaining catheter patency
- Preventing occlusion
-
Preparation Guidelines:
- Use preservative-free formulation
- Room temperature administration
- Discard unused portions
-
Safety Considerations:
- Isotonic solution
- No additives or medications
- Use within manufacturer's recommended timeframe
Clear Adhesive Dressing
-
Dressing Specifications:
Parameter Specification Material Transparent Polyurethane Film Adhesive Hypoallergenic, Low-Irritation Permeability Allows Moisture Vapor Exchange -
Functional Purpose:
- Temporary catheter stabilization
- Prevents accidental dislodgement
- Allows visual inspection of insertion site
-
Application Considerations:
- Gentle application
- Avoid excessive tension
- Regular site assessment
-
Clinical Precautions:
- Do not cover entire insertion site
- Replace if soiled or loose
- Monitor for skin irritation
Miscellaneous Equipment
Timer/Clock
-
Technical Specifications:
- Analog clock with clearly visible second hand
- Minimum readability: 1-second increments
- Recommended placement: Easily visible to all resuscitation team members
-
Critical Functions:
- Precise timing of resuscitation interventions
- Tracking duration of CPR
- Monitoring medication administration intervals
-
Clinical Importance:
Essential for accurate documentation and adherence to NRP time-sensitive protocols
Personal Protection Equipment
-
Glove Specifications:
Type Material Size Range Examination Gloves Latex-free Nitrile/Vinyl XS-XL -
Additional Protection Requirements:
- Fluid-resistant disposable gown
- Surgical mask or N95 respirator
- Eye protection (goggles or face shield)
-
Infection Control Standards:
Must comply with CDC and hospital-specific bloodborne pathogen exposure guidelines
Radiant Warmer
-
Device Specifications:
- Infrared heat generation
- Temperature range: 34-38°C
- Adjustable height and angle
- Electrical power: 120V/60Hz or 220V/50Hz
-
Thermal Management:
- Preset temperature control
- Rapid heat recovery
- Even heat distribution
-
Clinical Purpose:
Prevent hypothermia during immediate newborn care and resuscitation
Temperature Sensor
-
Sensor Characteristics:
- Digital infrared temperature measurement
- Accuracy: ±0.1°C
- Response time: < 2 seconds
-
Sensor Cover Specifications:
- Disposable, single-use
- Hygienic barrier material
- Compatible with radiant warmer models
-
Extended Monitoring Purpose:
Continuous temperature tracking during prolonged resuscitation efforts
Warmed Linens
-
Linen Specifications:
- Material: Soft, absorbent cotton or microfiber
- Recommended Size: 36" x 36" square
- Prewarming Temperature: 37-38°C
-
Thermal Management:
- Maintained in dedicated warming cabinet
- Temperature-controlled storage
- Rapid heat retention properties
-
Clinical Purpose:
Immediate thermal protection and drying of newborn post-delivery
Hat
-
Hat Specifications:
- Material: Soft, breathable cotton
- Sizes: Preemie, Newborn, Infant
- Color: Typically white or pastel
- Elastic or adjustable band
-
Thermal Regulation:
- Covers approximately 25-30% of body heat loss area
- Insulation factor: Minimal heat conductivity
-
Clinical Rationale:
Prevents significant heat loss through head in newborns, crucial for thermoregulation
Tape
-
Tape Specifications:
Width Material Adhesive Type 1/2 inch Hypoallergenic medical paper Gentle, skin-friendly adhesive 3/4 inch Flexible cloth or paper Moisture-resistant -
Clinical Applications:
- Securing endotracheal tubes
- Attaching monitoring leads
- Fixing IV lines
-
Performance Characteristics:
Hypoallergenic, low-trauma removal, maintains adhesion in humid environments
Intraosseous Needle
-
Device Specifications:
- Length: 15-25 mm
- Gauge: 15-18G
- Material: Stainless steel with beveled tip
- Compatibility: Multiple insertion sites (proximal tibia, distal tibia)
-
Emergency Access Characteristics:
- Rapid vascular access alternative
- Success rate: 90% first attempt
- Insertion time: < 30 seconds
-
Clinical Rationale:
Optional emergency vascular access when peripheral IV is challenging or impossible
Preterm Baby Protection
-
Protective Covering Specifications:
- Type: Food-grade polyethylene
- Size: 1-gallon zip-lock or plastic wrap
- Thickness: 2-3 mil
- Transparency: Clear
-
Thermal Management:
- Reduces evaporative heat loss
- Maintains body temperature for extremely premature infants
- Protective barrier against environmental contamination
-
Clinical Application:
Immediate thermal protection for infants < 28 weeks gestation
Thermal Mattress
-
Mattress Specifications:
- Material: Waterproof, heat-conductive polymer
- Size: Fits standard radiant warmer platforms
- Temperature Range: 34-38°C
- Power Source: Electrical, low-voltage
-
Thermal Regulation Features:
- Rapid temperature stabilization
- Even heat distribution
- Moisture-resistant surface
-
Clinical Purpose:
Continuous thermal support during extended resuscitation and stabilization
Size 00 Laryngoscope Blade
-
Blade Specifications:
- Length: 70-80 mm
- Width: 10-12 mm
- Material: Stainless steel or disposable plastic
- Type: Straight Miller blade
-
Technical Characteristics:
- Designed for neonatal intubation
- Optimal for premature and low birth weight infants
- Minimal tissue trauma design
-
Clinical Application:
Optional advanced airway management tool for specialized resuscitation scenarios
Transport Incubator
-
Incubator Specifications:
- Internal Dimensions: 70 x 40 x 30 cm
- Temperature Range: 32-38°C
- Humidity Control: 50-80%
- Power Source: Battery and AC adapter
- Weight: 15-20 kg
-
Advanced Features:
- Integrated oxygen monitoring
- Shock-absorbing suspension
- Transparent polycarbonate shell
- Emergency oxygen supply
-
Clinical Purpose:
Maintain stable thermal and respiratory environment during infant transfer between medical facilities